1.33ft in
8.92ft in
6.25ft in
12.25ft in
10.17ft in
12.5ft in
2.67ft in
15.5ft in
12.67ft in
11.5ft in
28.17ft in
48 degrees
57 degrees
42 degrees
8.33ft in
All dimensions are approximate and based on Bridgestone 875/65R29 VLTS L4 radial tires.
12.5ft in
763cu in
398hp
Cat C13 ACERT
The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.6 kg of refrigerant which has a CO2 equivalent of 2.288 metric tonnes.
1627lb ft
1609lb ft
398hp
1518lb ft
430hp
436hp
404hp
398hp
404hp
436hp
442hp
1505lb ft
406hp
412hp
412hp
417hp
1617lb ft
373hp
373hp
378hp
378hp
1602lb ft
436hp
436hp
78402lb
3.9mph
7.4mph
13.1mph
23.3mph
Maximum travel speed in standard vehicle with empty bucket and standard L4 tires with 914 mm (36 in) roll radius.
4.3mph
8.5mph
15mph
24.5mph
78402lb
Weight based on a machine configuration with Bridgestone 875/65R29 VLTS L4 radial tires, full fluids, operator, standard counterweight, cold start, roading fenders, Product Link, open differential axles, secondary steering, sound suppression, and a 6.1 m3 (8.0 yd3) GP bucket with BOCE.
For 6.1 m3 (8.0 yd3) general purpose buckets with BOCE.
Weight based on a machine configuration with Bridgestone 875/65R29 VLTS L4 radial tires, full fluids, operator, standard counterweight, cold start, roading fenders, Product Link, open differential axles (front/rear), secondary steering, sound suppression, and a 6.1 m3 (8.0 yd3) general purpose bucket with BOCE.
4.6-12.0 m (6.0-15.75 yd)
Fixed
Oscillating ?13 degrees
22.5in
10.1 s
4975 psi
Variable Displacement Piston
119 gal/min
63 gal/min
3159 psi
5.3 s
1.7 s
3.1 s
10.1 s
Brakes meet ISO 3450:2011 standards
For a machine configuration as defined under "Weight."
Full compliance to ISO 143971:2007 Sections 1 thru 6.
Full compliance to ISO (2007) 143971 Sections 1 thru 6, which requires 2% verification between calculations and testing.
58450lb
46473lb
49368lb
14gal
112.5gal
9.8gal
5.5gal
48gal
20.3gal
24.3gal
24.3gal
*Distance of 15 m (49.2 ft), moving forward in second gear ratio.
**For machines in European Union countries and in countries that adopt the "EU Directives."
***European Union Directive "2000/14/EC" as amended by "2005/88/EC."
*Distance of 15 m (49.2 ft), moving forward in second gear ratio.
72 dB(A)
112 dB(A)
78 dB(A)*
72 dB(A)
109 LWA***
ROPS/FOPS meet ISO 3471:2008 and ISO 3449:2005 Level II standards
4.6-12.0 m (6.0-15.75 yd)
Tier 3/Stage IIIA
Tier 4/Stage IV
Cat C13 ACERT
398hp
1627lb ft
5.2in
6.2in
763cu in
The power ratings apply at the stated speed when tested under the reference conditions for the specified standards.
The net power advertised is the power available at the flywheel when the engine is equipped with fan, alternator, air cleaner and aftertreatment.
The gross power advertised is with the fan at maximum speed.
1518lb ft
436hp
Cat C13 ACERT
412hp
373hp
1617lb ft
1505lb ft
5.2in
6.2in
763cu in
Cat engine with ACERT Technology ? meets Tier 2/Stage II, Tier 3/Stage IIIA equivalent emission standards.
75 dB(A)
112 dB(A)
78 dB(A)
The sound values indicated are for specific operating conditions only. Machine and operator sound levels will vary at different engine and/or cooling fan speeds. Hearing protection may be needed when the machine is operated with a cabin that is not properly maintained, or when the doors and/or windows are open for extended periods or in a noisy environment.
*For a standard machine configuration, measured according to the procedures specified with the cooling fan speed set at maximum value.
**For a standard machine configuration, measured according to the procedures specified. The measurement was conducted under the following conditions: distance of 15 m (49.2 ft), moving forward in second gear ratio with the cooling fan speed set at maximum value.
The sound values indicated are for specific operating conditions only. Machine and operator sound levels will vary at different engine and/or cooling fan speeds. Hearing protection may be needed when the machine is operated with a cabin that is not properly maintained, or when the doors and/or windows are open for extended periods or in a noisy environment.
72 dB(A)
112 dB(A)
78 dB(A)
*For a standard machine configuration, measured according to the procedures specified with the cooling fan speed set at maximum value.
**For a standard machine configuration, measured according to the procedures specified. The measurement was conducted under the following conditions: distance of 15 m (49.2 ft), moving forward in second gear ratio with the cooling fan speed set at maximum value.